Chen Xi,Xiao Yanfang,Ding Yang,Hong Weitao,Mai Lijun,Zeng Xuan,A method for the simultaneous determination of 12 antipsychotic drugs and their main metabolites in human serum[J].SICHUAN MENTAL HEALTH,2026,(2):140-148
A method for the simultaneous determination of 12 antipsychotic drugs and their main metabolites in human serum
DOI:10.11886/scjsws20251114002
English keywords:Antipsychotic drugs  Serum drug concentration  UPLC-MS/MS
Fund projects:2023年潮州市第三批科技专项(项目名称:基于药物基因组学和血药浓度监测指导的棕榈酸帕利哌酮长效针剂个体化用药研究,项目编号:202303GY02)
Author NameAffiliationPostcode
Chen Xi 1The Third People's Hospital of Chaozhou, Chaozhou 521041, China 521041
Xiao Yanfang 2Guangzhou Hybribio Medical Laboratory, Guangzhou 510555, China 510555
Ding Yang 1The Third People's Hospital of Chaozhou, Chaozhou 521041, China 521041
Hong Weitao 1The Third People's Hospital of Chaozhou, Chaozhou 521041, China 521041
Mai Lijun 2Guangzhou Hybribio Medical Laboratory, Guangzhou 510555, China 510555
Zeng Xuan* 3The First People's Hospital of Foshan (Affiliated Foshan Hospital of Southern University of Science and Technology), Foshan 528000, China 528000
Hits:
Download times:
English abstract:
      Background Monitoring the blood concentrations of antipsychotic drugs and their metabolites can guide the adjustment of clinical treatment plans, improving therapeutic efficacy while reducing adverse effects. However, there is currently a lack of a method that can accurately and efficiently quantitatively detect multiple antipsychotic drugs and their metabolites.Objective To establish a ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous identification and quantitation of 12 antipsychotic drugs and their main metabolites in human serum.Methods Using UPLC-MS/MS technology, protein precipitation method was employed for sample pretreatment. An Agela Technologies Durashell C8 chromatographic column (50 mm×3.0 mm, 5 μm) was selected for chromatographic separation with gradient elution. The flow rate was 0.4 mL/min, and the total analysis time was 5 minutes. The column temperature was 40℃. The mass spectrometry detection was carried out in the multiple reaction monitoring (MRM) mode, and the isotope internal standard method was used for quantification.Results The relative standard deviation (RSD) of the internal standard normalization matrix effect factor for 12 antipsychotic drugs and their main metabolites at low and high quality concentrations was all less than 15%. The extraction recovery rate was 85% to 115%. They showed good linear relationships within their respective standard curve ranges (r>0.995). At low, medium, and high quality concentrations, the accuracy was 85.24% to 114.71%, and the RSD of intra-batch and inter-batch precision was all ≤14.15%, with good stability.Conclusion All the analytical performance indicators of this method meet the verification requirements, providing an analytical means for the quantitative detection of antipsychotic drugs and their main metabolites in human serum. [Funded by The Third Batch of Science and Technology Projects in Chaozhou City in 2023 (number, 202303GY02)]